Hardy Enviro Bench Scales Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Waage Hardy Enviro Bench Scales herunter. Hardy Enviro Bench Scales User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Enviro™ Series

User’s Guide Enviro™ Series Checkweighing Instrument © 2009 by Hardy Instruments, Inc. Document Part Number 0596-0315-01 Revision B

Seite 2

Section 3: Installation 12/09 5 0596-0315-01 Rev B 2. Remove the 120 VAC plug from the end of the power cord and attach a proper 220-240

Seite 3 - Enviro™ Series Instrument

Section 3: Installation 12/09 6 0596-0315-01 Rev B 3.2.4 Powering Up the Indicator The Indicator performs a warm-up cycle.  The Indica

Seite 4 - Table of Contents

Section 3: Installation 12/09 7 0596-0315-01 Rev B Section 4 Programming Configuration 4.1. OVERALL STEPS Follow these steps to progr

Seite 5

Section 6: Serial I/O 12/09 8 0596-0315-01 Rev B 4.3. KEYPAD FUNCTIONS, PROGRAMMING MODE. This chart shows what action will be taken w

Seite 6 - 1.2. SPECIFICATIONS

Section 6: Serial I/O 12/09 9 0596-0315-01 Rev B 4.5. PROGRAMMING STEPS Setup Menu 1. Press and hold the Program/Enter key or press S1

Seite 7 - Section 2: Service Policy

Section 6: Serial I/O 12/09 10 0596-0315-01 Rev B P: Programming Port 1 Parity setting: The display will indicate p along with the curre

Seite 8 - Section 3 Installation

Section 6: Serial I/O 12/09 11 0596-0315-01 Rev B Opid: Include ID data with transmitted data: This determines whether or not to include

Seite 9 - Department

Section 6: Serial I/O 12/09 12 0596-0315-01 Rev B Cust: Custom units. The display will indicate cust and the current selection, either y

Seite 10 - 3.2.3 Remote switches

Section 6: Serial I/O 12/09 13 0596-0315-01 Rev B Press over/under/next, units or tare to change the selection. Press Program/Enter to en

Seite 11 - Powering Up the Indicator

Section 6: Serial I/O 12/09 14 0596-0315-01 Rev B X.xxupd: Display microvolts per division: This is a reference to display the current m

Seite 13 - 4.4. MENU ACCESS

Section 6: Serial I/O 12/09 15 0596-0315-01 Rev B Section 5 Calibrating the Indicator 5.1 Introduction  Calibration can be performed

Seite 14 - 4.5. PROGRAMMING STEPS

Section 6: Serial I/O 12/09 16 0596-0315-01 Rev B 5.2 Single Point Calibration Procedure Press and hold the PROGRAM/ENTER key until “SE

Seite 15 - Section 6: Serial I/O

Section 6: Serial I/O 12/09 17 0596-0315-01 Rev B Displays “LOAd1”, then raw counts Apply test weights to scale. Press PROGRAM/ENTER ke

Seite 16 - Config Menu

Section 6: Serial I/O 12/09 18 0596-0315-01 Rev B 5.3 Multipoint Calibration Press and hold the PROGRAM/ENTER key until “SEtUP is displ

Seite 17

Section 6: Serial I/O 12/09 19 0596-0315-01 Rev B When display shows correct test weight press PROGRAM/ENTER Displays “LOAd1”, “LOAd2”,

Seite 18 - APP Menu

Section 6: Serial I/O 12/09 20 0596-0315-01 Rev B 5.4 Service Sealing Commercial Applications Scales used in a commercial application

Seite 19

Section 6: Serial I/O 12/09 21 0596-0315-01 Rev B Section 6 Serial I/O 6.1 INTRODUCTION The Enviro™ Series Indicator is equipped with 2

Seite 20 - 5.1 Introduction

Section 6: Serial I/O 12/09 22 0596-0315-01 Rev B Remote display Please see the Enviro™ Series Printer Addendum for a list of suggested 3r

Seite 21

Section 7: Operations 12/09 23 0596-0315-01 Rev B Section 7 Operations 7.1. BASIC SCALE OPERATIONS Upon power up the Indicator perfor

Seite 22

Section 7: Operations 12/09 24 0596-0315-01 Rev B 3. Place container/object on scale (Tare weight). 4. Press the tare key. 5. Place ma

Seite 23

Enviro™ Series Instrument Document Part Number 0596-0315-01 Revision B Hardy Instruments Inc. 9440 Carroll Park Drive, Suite 150 San Diego, CA 921

Seite 24

Section 7: Operations 12/09 25 0596-0315-01 Rev B Port 1 set to Auto and Aout set to no. 1. After weight is applied, and if the weight i

Seite 25 - 5.4 Service Sealing

Section 7: Operations 12/09 26 0596-0315-01 Rev B 2. Weight on the scale must now be removed to less than .5 grads before the next accumu

Seite 26 - Section 6 Serial I/O

Section 7: Operations 12/09 27 0596-0315-01 Rev B 3. Press Program/Enter to display Hold X, where X is either Y or N. 4. Press Over/Unde

Seite 27 - Computer output

Section 7: Operations 12/09 28 0596-0315-01 Rev B 10. With the desired selection displayed, press Program/Enter to display units. With u

Seite 28 - Section 7 Operations

Section 7: Operations 12/09 29 0596-0315-01 Rev B 23. The entire under bar graph, the entire accept, and the first segment of the over ba

Seite 29 - Weight Accumulation

Section 8: Service and Maintenance 12/09 30 0596-0315-01 Rev B Section 8 Service & Maintenance 8.1. EXPANDED DISPLAY MODE The Env

Seite 30 - Section 7: Operations

Section 9: Parts 12/09 31 0596-0315-01 Rev B Section 9 Parts List IP 69k Model ITEM PART # QTY DESCRIPTION 1 29006 1 FRONT PANEL

Seite 31

Section 9: Parts 12/09 32 0596-0315-01 Rev B IP 69k Reference Drawing

Seite 32

Appendix I Keypad Reference Tb3 connections to keypad shown below. 01/10 33 0596-0315-01 Rev. B

Seite 33

Enviro Series Instrument USER’S GUIDE Document Part Number 0596-0315-01 B

Seite 34

Section 1: General Information 12/09 ii 0596-0315-01 Rev B Table of Contents SECTION 1 ...

Seite 35 - 8.2 SCALE MAINTENANCE

12/09 iii 0596-0315-01 Rev B 8.1. ...30 Ex

Seite 36 - Section 9 Parts List

Section 1 General Information 1.1. INTRODUCTION The Enviro™ Series instrument is designed for light capacity, general purpose use. It is also de

Seite 37 - Section 9: Parts

Section 2: Service Policy 12/09 2 0596-0315-01 Rev B Section 2 Service Policy Information 2.1. GENERAL SERVICE POLICY Customers are

Seite 38 - Appendix I Keypad Reference

Section 3: Installation 12/09 3 0596-0315-01 Rev B Section 3 Installation 3.1. PRIOR TO INSTALLATION 1. Unpack and Check contents 2

Seite 39 - Enviro Series Instrument

Section 3: Installation 12/09 4 0596-0315-01 Rev B   IMPORTANT INSTALLATION NOTICE    All load cells, load cell cables, and interc

Kommentare zu diesen Handbüchern

Keine Kommentare